CTL Components plc
CTL Components plc CTL Components plc CTL Components plc CTL Components plc

Certification

Certificates

MV Joints
CTL Medium Voltage joints are tested in accordance with Cenelec HD629.1S1.

Test Description

 

Cable Type & System Voltages

Polymeric 12 kV (Um)

Paper & Transition 12 kV (Um)

DC Withstand 15 min (kV)

38

38

AC Withstand 5 min (kV)

28.5

28.5

Partial Discharge <10pc (kV)

11

-

Impulse Voltage (kVp)

95

95

Heat Cycling Air & Water (kV)

16

9.5

 

LV Heatshrink Products
All CTL C-Shrink moulded shapes and heatshrink tubing meet or exceed EA-1509-11.

Properties

Typical Results

Test Method

Cont. Operating Temp.

-55º to +110ºC

-

Tensile Strength

15 MPa

IEC 540

Ultimate Elongation

400%

IEC 540

Heat Shock

No Damage

ASTM D2671

Dielectric Strength

15 kV/mm

ASTM D2671

Water Absorption

<0.1%

ASTM D570

Flammability

Self Extinguishing

ASTM D635

 

MV Terminations
CTL Medium Voltage Terminations are tested in accordance with VDE0278 (CENELEC HD629.1S1) and IEC502.

Test Description

Cable Type &

System Voltages

Polymeric

Paper

17.5 kV

(Um)

24 kV

(Um)

36 kV

(Um)

12 kV

(Um)

DC Withstand 15 min (kV)

52

76

114

38

AC Withstand Dry 5 min (kV)

39

57

85

28.5

AC Withstand Wet 1 min (kV)

35

51

76

25.5

Partial Discharge <10pc (kV)

15

22

33

-

Impulse Voltage (kVp)

95

125

194

95

Heat Cycling Air (kV)

23

32

47.5

9.5

Salt Fog 1000 hr (kV)

11

16

24

8

 


LV Cable Joints
All CTL LV cable joints hold test certificate CENELEC HD 623.S1/DIN VDE 0278, now renamed EN50393:2006. (BS6910 and BS7888 standards are now obsolete.)

ISO 9001:2000
All companies within CTL Components Group plc are fully acredited to BS EN ISO 9001:2008. CTL is a member of the British Standards Institution.

Tables only show some of the parameters tested. Full copies of Test Certificates are available.

For more information please contact www.filoform.com